Thermal Properties - Test Data

Description: This attractive flat wall panel utilizes the Mesa profile on both panel surfaces. The product is designed for interior partition as well as exterior wall applications. This Tecfoam panel is filled with non CFC polyurethane modified isocyanurate foam achieving R-values up to 40.0.
Dimensions: Nominal 36" or 42" coverage; Thickness (T) – 2", 2 ½", 3", 4" and 5".
Material:
Exterior (Wall) - 24 ga. steel (std). 22 ga. also available.
Exterior (Partition) - 26 ga. steel (std.) 24 and 22 ga. also available.
Interior - 26 ga. steel (std.) 24 and 22 ga. also available.
Finish Options:
Exterior - USDA White
Signature® 200 (silicone polyester)
Signature® 300 (Kynar 500®/Hylar 5000® )
Interior - USDA White (standard)
Signature® 200 (silicone polyester)
Colors: IPS Panel Color and Finish Guide
Texture: The exterior and interior skins are embossed only.
Length: The maximum recommended length is 30' 0". Contact IPS for panel length options. IPS offers standard details for stack joint applications for walls over 30' 0" high.
Fasteners: Concealed, 14 ga. steel clip.

Test Data

Test Purpose Procedure Results
Thermal Resistance Determines insulating
properties of the panels
ASTM C236
Guarded Hot Box
Good R values for an HCFC Foam System
(see published values for panel type and thickness)

 

 

 

 

Air
Leakage
Measures air leakage
through the panel joints
ASTM E283
Chamber Method
The leakage rate for panel will not exceed 0.01
CFM/SF at 40 psf pressure differential

 

 

 

 

Water Penetration Measures water leakage
through the panel joints
ASTM E331
Chamber Method
No water penetration at pressure differential of
50 psf

 

 

 

 

Strength Determines the load/span
properties of the roof and wall
panels
ASTM E72
Chamber Method
Panel load/span and deflection tables
are available

 

 

 

 

Surface
Burning
Determines the surface
burning characteristics of the
core and panels.
Underwriters
Laboratories UL 723
(ASTM E84)
Core Material (5")
Flame Spread 20*
Smoke Developed 400

Finished Panel
2" to 5" Wall Panel
Flame Spread 15*
Smoke Developed 250 - 450

Southwest
Research
Institute
ASTM E84
Finished Panel
5" Wall Panel
Flame Spread 10
Smoke Developed 130
Factory
Mutual
ASTM E84
Core Material (5")
Flame Spread 25*
Smoke Developed 180

 

 

 

 

Room
Fire Test
Evaluates the burning of roof
and wall panels in a room
configuration
Factory Mutual
STD. 4880 (1994)
(UBC 26-3)
Panel is rated
Class 1 to 30 ft. high, 5 in. max. thickness

*The numerical flame spread rating is not intended to reflect hazards
presented by this or any other material under actual fire conditions.

Thermal Properties

IPP Wall Panel
Product Code Thickness "U" Factor "R" Factor
IPP 200 2" .063 16.0
IPP 250 2 1/2" .050 19.9
IPP 300 3" .042 23.9
IPP 400 4" .031 31.9
IPP 500 5" .025 40.0

Note: Insulation values determined by tests conducted in accordance
with ASTM C236 at a mean temperature of 75 degrees F., winter
condition corrected to 15 mph outside and still inside.