RWP ROOF/WALL PANEL

ESP WALL PANEL

IPP WALL/PARTITION PANEL

EWP WALL PANEL

 

 

RWP Roof/Wall Panel

Thermal Properties - Test Data

Description: The RWP Panel functions well as a roof or wall panel when used in conjunction with pre-engineered building framing systems. The product features an over-lapping major rib at the panel sidelap. Exposed fasteners are located in the major ribs when the panel is used as a roof and in the pan when the panel is used in a wall application. This Tecfoam panel is filled with non CFC polyurethane modified isocyanurate foam achieving R-values up to 35.7.
Dimensions: Nominal 36" coverage; Thickness (T) – 1-½", 2", 2-½" and 3". Contact IPS regarding the availability of 4" and 5" thick panels.
Material:
Exterior - 26 ga. steel (std). 24 and 22 ga. also available.
Interior - 26 ga. steel (std). 24 and 22 ga. also available.
Finish Options:
Exterior - Galvalume Plus®
Signature® 200 (silicone polyester)
Signature® 300 (Kynar 500®/Hylar 5000®)
Interior - USDA White (standard)
Signature® 200 (silicone polyester)
Colors: IPS Panel Color and Finish Guide
Texture: The exterior skin is smooth as a standard and available embossed as an option. The interior skin is embossed only.
Length: The maximum recommended length is 35' 0". Contact IPS for panel length options.
Fasteners: Exposed - hex head with neoprene washers.

Test Data

Test Purpose Procedure Results
Thermal Resistance Determines insulating
properties of the panels
ASTM C236 Guarded Hot Box Good R values for an HCFC Foam System
(see published values for panel type and thickness)

 

 

 

 

Strength Determines the load/span
properties of the roof and wall panels
ASTM E72 Chamber Method Panel load/span and deflection tables
are available

 

 

 

 

Wind
Uplift
Determines uplift resistance
of roof panels in high winds
Factory Mutual STD. 4471(1995) RWP Roof Panels have a class 1-60 rating with a
5' 0" purlin spacing

RWP Roof Panels qualify for a Class SH Hailstorm rating

 

 

 

 

Surface Burning Determines the surface burning
characteristics of the core and panels
Factory Mutual
ASTM E84
Core Material (5")>
Flame Spread 25*, Smoke Developed 180

 

 

 

 

Room Fire Test Evaluates the burning of roof
and wall panels in a room configuration
Factory Mutual
STD. 4880 (1994)
(UBC 26-3)
All wall and roof panels are rated Class 1 to 30 ft. high, 5 in. max. thickness

 

 

 

 

Roof Covering Fire Test Evaluates the burning of roof
covering from external fire
Factory Mutual STD. 4471 (1995)
(ASTM E108)
The RWP Roof Panel is rated Class A

*The numerical flame spread rating is not intended to reflect hazards
presented by this or any other material under actual fire conditions.

Thermal Properties

RWP Roof or Wall Panel
Product Code Thickness "U" Factor "R" Factor
RWP 150 1 1/2" .082 12.2
RWP 200 2" .064 15.6
RWP 250 2 1/2" .053 18.9
RWP 300 3" .045 22.3
RWP 400 4" .034 29.0
RWP 500 5" .028 35.7

Note: Insulation values determined by tests conducted in accordance
with ASTM C236 at a mean temperature of 75 degrees F., winter
condition corrected to 15 mph outside and still inside.

back to top

Legal Privacy Site Map Company Store Career Contact Us