SSP ROOF PANEL

RWP ROOF/WALL PANEL

ESP WALL PANEL

IPP WALL/PARTITION PANEL

ABP WALL PANEL

EWP WALL PANEL

DesignerTM Series

 

SSP Roof Panel with VersaLok™

Thermal Properties - Test Data

Description:
The SSP Standing Seam Roof Panel with the patented VersaLok™ sidelap connection. The panel is a true factory foamed-in-place trapezoidal roof panel with a standing seam offering superior weathertightness. With the IPS patented VersaLok™ sidelap, the roof panels snap together before being mechanically seamed. This Tecfoam panel is filled with non CFC polyurethane modified isocyanurate foam achieving R-values up to 39.5.
Dimensions:
Nominal 36" coverage; Thickness (T) – 2", 2 ½", 3", 4" and 5".
Material:
Exterior - 24 ga. steel (std).
26, 22 ga. also available.
Interior - 26 ga. steel (std).
24, 22 ga. also available.
Finish
Options:
Exterior - Galvalume Plus®
Signature® 200 (silicone polyester)
Signature® 300 (Kynar 500®/Hylar 5000®)
Interior - USDA White (standard)
Signature® 200 (silicone polyester)
Colors:
IPS Panel Color and Finish Guide
Texture:
The exterior skin is smooth as a standard and available embossed as an option. The interior skin is embossed only.
Length:
The maximum recommended length is 35' 0". Contact IPS for panel length options.
Fasteners:
Concealed clip, 14 ga. steel base with an 18 ga. steel tab.

Test Data

Test Purpose Procedure Results
Thermal Resistance Determines insulating
properties of the panels
ASTM C236
Guarded Hot Box
Good R values for an HCFC Foam System
(see published values for panel type and thickness)

 

 

 

 

Air Leakage Measures air leakage
through the panel joints
ASTM E283
Chamber Method
The leakage rate for the SSP panel will not exceed
0.01 CFM/SF at 40 psf pressure differential

 

 

 

 

Water Penetration Measures water leakage
through the panel joints
ASTM E331
Chamber Method
No water penetration at pressure differential of
50 psf for the SSP panel

 

 

 

 

Strength Determines the load/span
properties of the roof and wall panels
ASTM E72
Chamber Method
Panel load/span and deflection tables
are available

 

 

 

 

Wind
Uplift
Determines uplift resistance of
roof panels
in high winds
Underwriters
Laboratories
UL 580
SSP Roof Panels have a Class 90 rating with
a 7'- 0" purlin spacing
Factory Mutual
STD. 4471(1995)
SSP Roof Panels have a Class 1-75 and 1-90 rating with a 5'- 0" purlin spacing.

SSP Roof Panels qualify for a Class SH Hailstorm rating
Determines ultimate uplift
capacity of roof panels
ASTM E1592 SSP Roof Panels have an ultimate uplift capacity of
100 psf with a 6'- 0" purlin spacing

 

 

 

 

Surface Burning
Determines the surface burning characteristics of 
the core and panels
Underwriters
Laboratories UL 723
(ASTM E84)

Core Material (5")
Flame Spread 20*
Smoke Developed 400

Finished Panels
2" to 5" Panel
Flame Spread 15*
Smoke Developed 
250 - 450

Factory Mutual
ASTM E84
Core Material (5")
Flame Spread 25*, Smoke Developed 180

 

 

 

 

Room
Fire Test
Evaluates the
burning of  roof and wall panels in a
room configuration
Factory Mutual STD. 4880 (1994)
(UBC 26-3)
All wall and roof panels are rated Class 1 to 30 ft. high, 5 in. max. thickness

 

 

 

 

Roof Covering Fire Test Evaluates the
burning of
roof covering
from external fire
Underwriters
Laboratories
UL 790
(ASTM E108)
The SSP Roof Panel
is rated Class A
Factory Mutual
STD. 4471 (1995)
(ASTM E108)
The SSP Roof Panel
is rated Class A

*The numerical flame spread rating is not intended to reflect hazards
presented by this or any other material under actual fire conditions.

Thermal Properties

SSP Roof Panel
Product Code Thickness "U" Factor "R" Factor
SSP 200 2" .067 14.9
SSP 250 2 1/2" .053 19.0
SSP 300 3" .043 23.1
SSP 400 4" .032 31.3
SSP 500 5" .025 39.5

Note: Insulation values determined by tests conducted in accordance
with ASTM C236 at a mean temperature of 75 degrees F., winter
condition corrected to 15 mph outside and still inside.