| Test |
Purpose |
Procedure |
Results |
| Thermal Resistance |
Determines insulating
properties of the panels |
ASTM C236
Guarded Hot Box |
Good R values for an HCFC Foam System
(see published values for panel type and thickness) |
|
|
|
|
| Air Leakage |
Measures air leakage
through the panel joints |
ASTM E283
Chamber Method |
The leakage rate for the SSP panel will not exceed
0.01 CFM/SF at 40 psf pressure differential |
|
|
|
|
| Water Penetration |
Measures water leakage
through the panel joints |
ASTM E331
Chamber Method |
No water penetration at pressure differential of
50 psf for the SSP panel |
|
|
|
|
| Strength |
Determines the load/span
properties of the roof and wall panels |
ASTM E72
Chamber Method |
Panel load/span and deflection tables
are available |
|
|
|
|
Wind
Uplift |
Determines uplift resistance of
roof panels
in high winds |
Underwriters
Laboratories
UL 580 |
SSP Roof Panels have a Class 90 rating with
a 7'- 0" purlin spacing |
Factory Mutual
STD. 4471(1995) |
SSP Roof Panels have a Class 1-75 and 1-90 rating with a 5'- 0" purlin spacing.
SSP Roof Panels qualify for a Class SH Hailstorm rating |
Determines ultimate uplift
capacity of roof panels |
ASTM E1592 |
SSP Roof Panels have an ultimate uplift capacity of
100 psf with a 6'- 0" purlin spacing |
|
|
|
|
Surface Burning |
Determines the surface burning characteristics of
the core and panels |
Underwriters
Laboratories UL 723
(ASTM E84)
|
Core Material (5")
Flame Spread 20*
Smoke Developed 400
Finished Panels
2" to 5" Panel
Flame Spread 15*
Smoke Developed
250 - 450 |
Factory Mutual
ASTM E84 |
Core Material (5")
Flame Spread 25*, Smoke Developed 180 |
|
|
|
|
Room
Fire Test |
Evaluates the
burning of roof and wall panels in a
room configuration |
Factory Mutual STD. 4880 (1994)
(UBC 26-3) |
All wall and roof panels are rated Class 1 to 30 ft. high, 5 in. max. thickness |
|
|
|
|
| Roof Covering Fire Test |
Evaluates the
burning of
roof covering
from external fire |
Underwriters
Laboratories
UL 790
(ASTM E108) |
The SSP Roof Panel
is rated Class A |
Factory Mutual
STD. 4471 (1995)
(ASTM E108) |
The SSP Roof Panel
is rated Class A |